Surgical Drains: Indications, Types, and Complications (2024)

Peer Reviewed

Soft Tissue Surgery

Management of wound drains is a vital component of wound care as incorrect management of these drains can adversely affect the patient and their recovery.

April 12, 2019|

Issue: May/June 2019

Mallory Watson

DVM

Dr. Mallory Watson graduated from Louisiana State University School of Veterinary Medicine in 2016. Immediately after graduation, she completed a rotating internship at Oklahoma State University, followed by a surgical internship at BluePearl Veterinary Partners in Spring, Texas. She is currently participating in a surgical internship at Austin Veterinary Emergency and Specialty Center in Austin, Texas. Dr. Watson’s goal is to become a Diplomate of the American College of Veterinary Surgeons. In her spare time, she enjoys cycling, hiking, and spending time with her golden retriever, Baylor.

Read Articles Written by Mallory Watson

Michael S. McFadden

MS, DVM, DACVS

Dr. McFadden graduated from Ross University School of Veterinary Medicine in 2006. He completed a rotating internship at Louisiana State University and a surgical residency at the University of Illinois. After his residency, Dr. McFadden stayed at the University of Illinois as a clinical assistant professor before moving on to private practice. He is currently the owner/ surgeon of Houston Mobile Veterinary Surgery in Houston, Texas.

Read Articles Written by Michael S. McFadden

Surgical Drains: Indications, Types, and Complications (1)

Photo Courtesy Bonnie G. Campbell, DVM, PhD, DACVS

Surgical drains are implants that allow removal of fluid and/or gas from a wound or body cavity. This broad definition includes nasogastric tubes, urinary catheters, vascular access ports, and ventriculoperitoneal shunts. However, covering all of these types of drains is beyond the scope of this review, which concentrates on drains used for wounds (traumatic or surgical), drains used in the peritoneal and pleural spaces, and negative pressure wound therapy. This review is part 1 of a 2-part series. Part 1 covers indications for drain use, types, benefits and drawbacks of each type, and common complications. Part 2 will cover drain placement techniques and postoperative care.

Indications

Drains can help the healing process by removing inflammatory mediators, bacteria, foreign material, and necrotic tissue.1 Drains can relieve pressure that can impair perfusion or cause pain, thereby decreasing morbidity and reducing inflammation; they enable monitoring for potential complications by allowing easy sampling of fluid during healing; and they can be used to address complications associated with dead space after a pathology report has determined that neoplasia resection is complete and margins are adequate.2

The main indications for drain use include the need to eliminate dead space, remove existing fluid or gas, and prevent accumulation of fluid or gas. Dead space develops between tissues after disruption of subcutaneous connective tissues; it is undesirable because the fluid that typically fills this void provides a prime medium for bacterial growth. A review of 228 cases (33 cats and 195 dogs) found that closed suction drains were used for closure of traumatic wounds in 47.1% of cases; closure after tumor removal for 26.5%; closure of nonhealing wounds for 17.6%; and single cases of abscess treatment, amputation, and traumatic hernia repair.3

Drain Types

Many types of drains are used in veterinary practice; some are commercially available and others can be made from catheters or tubing already present in most hospitals. The materials used for drains include latex, silicone, polyethylene, and polyvinyl chloride. The drain material determines which of several methods should be used to sterilize each type of drain. Material type also can affect wound healing because tissue reactions to different materials vary. Materials that cause the most reaction are red rubber catheters and latex; those that cause the least reaction are polyethylene, polyvinyl chloride, and silastic tubing (more biologically inert).1

Drains are classified by various systems: open or closed and passive or active. Passive drains rely on gravity, body movement, pressure differentials, or overflow to move fluid or gas; active drains use intermittent or continuous negative pressure to pull fluid or gas from a wound or body cavity. Typically, passive drains are open systems and active drains are closed systems because they rely on negative pressure that is created by the drain.

Passive Drains

Passive drains are made of latex, polypropylene, or silastic rubber. These include Penrose drains, the type most commonly used in veterinary practice.1,4 The ubiquitous use of Penrose drains in many small animal practices results from their being readily available, easy to place, and inexpensive. Penrose drains are made of soft, tubular, radiopaque latex; are available in a variety of widths; and can be easily cut to a desired length (FIGURE 1). These drains are most commonly used in wounds, after surgery where dead space is present, or when accumulation of fluid is anticipated. They work by capillary action, gravity, overflow, or fluctuations of pressure gradients caused by body movement.

FIGURE 1. Penrose drain. Commonly used after surgery, Penrose drains are radiopaque and available in a variety of sizes (the drain in this image is 3/8 x 12 inches).

Use of Penrose drains is not always appropriate. Their use for abdominal drainage is not recommended because intraperitoneal pressure changes during respiration can cause retrograde movement of fluid or gas back into the peritoneal cavity.1 Use of passive drains in the thoracic cavity is contraindicated because of the possibility of pneumothorax.

Although Penrose drains are tubular, fluid moves out of the body by capillary action along the external surface of the drain, not through the lumen. Drainage efficiency is directly proportional to the surface area of the drain. A common mistake made when using Penrose drains is to create fenestrations, which greatly decrease the functional surface area, thereby significantly decreasing the efficiency of the drain. In addition, fenestrations may increase the risk of tearing inside a wound, leaving foreign material that would require additional surgery to remove.

Because the action of Penrose and other passive drains relies on gravity, achieving optimal drainage depends on choosing the proper drain exit. These drains cannot be attached to suction because their soft, flimsy nature causes them to collapse, making suction ineffective. A passive drain should exit through a single stab incision, away from the primary incision, in the most dependent portion of the wound. Placing the drain exit in other areas can lead to decreased drain efficiency and fluid accumulation within the wound. The dorsal (or proximal) end of the drain should be either buried in the wound or secured with a single suture that penetrates the skin and is tied externally. When removing this drain, this external suture must first be cut to prevent tearing of the drain and potentially leaving drain fragments in the wound. Another common mistake when placing Penrose drains is making 2 stab incisions, 1 dorsal and 1 ventral (or distal), and exiting the drain through both incisions (FIGURE 2). Having the drain exit in 2 places increases the risk for infection and decreases drain efficiency.5 A dorsal exit will not increase drainage efficiency, and gravity will enable contaminants to move into the wound. Creating a dorsal exit also limits your ability to bury the ventral end of the drain in the deepest portion of the wound, thereby decreasing the drain’s effectiveness.1 Exceptions to this principle include wounds in the inguinal or axillary areas, where there is significant movement, which can lead to the drain acting as a 1-way valve and causing subcutaneous emphysema.1 In these areas, a second exit can allow air to escape; preferably, a closed suction drain can be used.

FIGURE 2. Incorrect placement of a Penrose drain. Having both a dorsal and a ventral exit does not increase drain efficiency and can increase risk for infection by allowing bacteria and other contaminants to enter the dorsal exit.

To further decrease the risk for ascending infection, passive drains should be covered with a sterile absorbent bandage that is placed and aseptically changed before any strike-through (exudate that has soaked the outer layer of the bandage) is present. Without a bandage, egressing fluid can lead to severe skin irritation and excoriation in addition to increasing the risk for ascending infection (FIGURE 3). In addition, uncovered drains are accessible for the patient to bite off, leaving the buried portion within the wound and requiring additional surgery to remove it. Placing bandages over the drain also provides a way to roughly estimate fluid production, which helps the clinician determine when to remove the drain.

FIGURE 3. Incorrect use of a Penrose drain, resulting in severe skin excoriation because of inappropriate care after placement. (A) The drain is unbandaged, and drainage covers the left forelimb.

FIGURE 3. Incorrect use of a Penrose drain, resulting in severe skin excoriation because of inappropriate care after placement. (B) After the hair was clipped and the area cleaned, the extent of the skin irritation can be appreciated.

Active Drains

Active drains are closed systems that collect fluid into a reservoir. This reservoir prevents saturation of bandage material, decreases the risk for ascending infection, and can limit exposure of hospital staff or other patients to contaminated fluid. Active drains apply an artificial pressure gradient to pull fluid or gas from a wound or body cavity. Negative pressure increases the efficiency of active over passive drains, enables placement of the drain exit in any position, can remove fluid against gravity if necessary, and can be used to collapse dead space. The negative pressure of active drains can be continuous or intermittent. Continuous negative pressure optimizes drain function and can reduce the amount of time the drain is in place. Continuous suction also decreases the opportunity for bacteria to proliferate in static fluid.1 Intermittent negative pressure should optimally be based on the volume of fluid or gas being evacuated. A negative pressure of 80 mm Hg allows fluid evacuation and collapses dead space without damaging the tissue in the area of the drain.6 The types of active drains described in this article are Jackson-Pratt drains and thoracostomy (chest) tubes.

Jackson-Pratt Drains

These commercially available drains are commonly used in veterinary practice (FIGURE 4). They apply continuous suction through a collapsible grenade-style collection reservoir. When the reservoir is collapsed and attached to the drain tubing, it creates negative pressure that pulls fluid through radiopaque fenestrated tubing. These systems are simple to use, available in different sizes, and can be cut to the desired length.

FIGURE 4. Commercially available closed suction Jackson-Pratt drain.

Closed suction drains can also be made from extension sets or butterfly catheters. Extension sets can be fenestrated and attached to a syringe. The plunger can be drawn back and held in place with a safety pin or hypodermic needle to maintain the desired amount of negative pressure (FIGURE 5).

Figure 5. Homemade closed suction drains created from supplies that are readily available in most hospitals. (A) Drain made from extension set and syringe.

Figure 5. Homemade closed suction drains created from supplies that are readily available in most hospitals. (B) Fenestrations made in the needle end of the extension set after the needle adapter has been removed.

Figure 5. Homemade closed suction drains created from supplies that are readily available in most hospitals. (C) Bobby pin used to hold the plunger and create the desired level of negative pressure; a needle or safety pin could also be used.

Similarly, a butterfly catheter can be adapted for use as a drain for small areas or smaller patients by cutting off the syringe adapter, fenestrating the tubing, and placing the needle into Vacutainer tubes (FIGURE 6). To avoid breaking or kinking the tubes during fenestration, take care to limit the size of the fenestrations to holes less than one-third the diameter of the tubing.

Figure 6. Simple closed suction system made from a butterfly catheter; good for use in small areas or small patients. Vacutainer tubes can be used to generate suction and act as collection systems. (A) A butterfly closed suction drain in a small patient.

Figure 6. Simple closed suction system made from a butterfly catheter; good for use in small areas or small patients. Vacutainer tubes can be used to generate suction and act as collection systems. (B) A prepared drain.

Regardless of the type of closed suction drain used, proper placement is crucial for optimal function. The fenestrated portion is buried in the deepest portion of the wound or where fluid accumulation is anticipated. The drain tubing is exited through the skin away from the primary incision or wound closure. Because any air that enters the system will affect the negative-pressure gradient, care must be taken to ensure that the system is closed. The wound closure or incision must also be completely closed. To avoid premature loss of the drain, the exit site must be sealed and the drain secured (FIGURE 7). In some instances, antibiotic or petroleum-based ointment placed over the incision or drain exit can help form an airtight seal. In addition, the drain exit is secured with purse-string and finger-trap sutures.

FIGURE 7. Correct placement of a Jackson-Pratt drain. The drain exits away from the primary incision; it does not have to be placed in a dependent area. Note the purse-string and finger-trap sutures (blue arrow) placed to ensure that air is not pulled in through the skin and to prevent inadvertent drain removal.

Thoracostomy Tubes

These drains are used to evacuate fluid or air from the pleural space. The tubes are made of latex or PCV and are flexible but resistant to collapse. Commercially available thoracostomy tubes have trocars to enable rapid placement. To prevent iatrogenic pneumothorax, thoracostomy tubes are always used as closed systems. They are also used as active drains; the suction is usually intermittent, although it can be continuous when fluid or gas are rapidly or continuously accumulating in the pleural space. These tubes are secured in a similar fashion to other closed suction drains; purse-string and finger-trap sutures ensure a seal at the tube entrance and prevent the drain from accidentally being pulled out.

The size of the chest tube should be appropriate for the condition being treated. A general recommendation is that the tube be approximately the same size as a mainstem bronchus (which can be approximated from a chest radiograph).7 However, a recent ex vivo study showed that the efficiency of small- and large-bore chest tubes in cadavers was similar for removing known amounts of air, low viscosity fluid, and high viscosity fluid.8 For cases of pyothorax, author M.S.M. has had to replace small-bore thoracostomy tubes with larger bore tubes. Many patients need thoracostomy tubes on both sides of the chest; for others, a unilateral chest tube is sufficient.

Placement of chest tubes may or may not require anesthesia. Most patients are anesthetized to reduce pain and prevent movement during placement, but for critically ill patients, anesthesia may not be needed (or may be risky). A small stab incision is made over the dorsal aspect of the 10th or 11th rib. Tubes are tunneled under the skin and muscle and should enter the thoracic cavity around the 7th or 8th intercostal space. Management of thoracostomy tubes requires extreme care; if they become open to the environment, they can cause a life-threatening pneumothorax.

In summary, advantages of active drains over passive drains include:

  • decreased risk for ascending infection
  • ability to be used in areas that are difficult to bandage
  • decreased risk for skin excoriation
  • accurate assessment of volume of fluid being produced
  • easy collection of fluid for cytology or chemical analysis with less possibility of environmental contamination of the fluid
  • ability to collapse dead space

Negative-Pressure Wound Therapy

Negative-pressure wound therapy (NPWT) is a type of closed, active drain system that uses subatmospheric pressures. It has been shown to improve wound perfusion.9,10 NPWT deceases interstitial edema, stimulates fibroplasia, and enhances angiogenesis, although the exact mechanisms of these actions are not completely understood.11 NPWT leads to earlier wound closure because of accelerated granulation tissue formation, reduced bacterial colonization, and reduced wound edema and exudate.9-11 Unlike the drains previously discussed, NPWT can be used in open wounds or incisions, providing access for treatment.

During drain placement, a coarse, open cell foam is laid directly over the wound and a specialized drain tubing is placed over the foam. An occlusive dressing is applied to create a seal around the wound; to create the negative pressure, this seal must be maintained. Tubing is attached to the drain unit and constant negative pressure is applied (FIGURE 8). A pressure of –125 mm Hg increases microvascular blood flow and is recommended; pressures greater than –400 mm Hg inhibit blood flow and should not be used.12

Figure 8. Negative-pressure wound therapy provides a way to remove exudate from a wound without requiring wound closure. (A) Large wound present after initial debridement.

Figure 8. Negative-pressure wound therapy provides a way to remove exudate from a wound without requiring wound closure. (B) Open cell foam placed in the wound bed.

Figure 8. Negative-pressure wound therapy provides a way to remove exudate from a wound without requiring wound closure. (C) Occlusive dressing applied to create a seal and maintain a closed system.

Figure 8. Negative-pressure wound therapy provides a way to remove exudate from a wound without requiring wound closure. (D) Drain placed in the occlusive dressing and connected to a vacuum source and collection system.

Indications for NPWT use in veterinary medicine include the following:11

  • acute and chronic wounds
  • abscesses
  • degloving injuries
  • burns
  • dehisced incisions
  • adjunct therapy for skin flaps and skin grafts
  • compartment syndrome
  • necrotizing fasciitis or severe vasculitis

NPWT is also beneficial after application of free skin grafts, especially during the first critical week after application.13 Because skin grafts are fenestrated, other drain techniques would be ineffective. The negative-pressure system may help stabilize the graft by reducing fluid accumulation under the graft and may help reduce the possibility of bacterial contamination and necrosis of the graft, thereby increasing the chances of success versus catastrophic failure.13 The recommended pressures for use over a skin graft are lower, –65 to –75 mm Hg.

Contraindications for NPWT use include the following:11

  • severe dermatitis or poor skin condition around the wound
  • large amounts of necrotic or devitalized tissue
  • coagulopathies
  • exposure of major vessels
  • open joints
  • wounds that contain neoplastic tissue
  • untreated osteomyelitis
  • a situation in which 24-hour care is not available should any NPWT apparatus malfunction

Complications and Failures

Inappropriate use of drains can lead to complications that include infection and increased overall patient morbidity. Inappropriate placement can also increase the risk for incision dehiscence or delayed/failed wound healing. Drains cannot compensate for inadequate debridement, inappropriate wound care, or improper surgical technique. With regard to closed suction drains, a retrospective study showed that the risk for major complications is low (4 [0.02%] of 228 patients) and the risk for minor complications is mild to moderate (35.3% of cats and 33.8% of dogs).3 Despite the low risk for major complications, drain placement can lead to the following issues.

Infection

Use of drains leads to higher rates of infection, the most common complication.14 One study showed an infection rate after clean surgeries in dogs to be 15.6%.3 Retrograde bacterial contamination, including nosocomial infection, can occur with high frequency but is significantly lower when closed suction drainage is used.15-17 In addition to ascending infection, foreign body reaction to the drain itself may make the wound more susceptible to infection.14 Recommendations for reducing the chance of bacterial contamination include removing the drain as soon as indicated and following strict aseptic protocols during placement and management.3

Vascular Damage

During placement of active drains, care should be taken to avoid placing them near arteries to avoid pressure necrosis of the arterial wall.18 One report describes 2 patients in whom placement of an active drain was followed by hemorrhage; both patients recovered after drainage was temporarily discontinued and fluid resuscitation provided.18

Spread of Neoplastic Cells

In surgical oncology, use of drains is controversial. Although many surgical oncology patients have areas of dead space or rely on complex skin reconstruction that can benefit from drain placement, drains can disrupt tissue away from the primary surgery site and seed these areas with neoplastic cells.2 This effect increases the area that has to be addressed if margins are not adequate and additional surgery, chemotherapy, or radiation therapy is required.

Dehiscence

Other complications associated with drains typically result from improper placement and tube size selection. Poor placement can lead to incision infection or dehiscence, which could potentially lead to herniation of abdominal viscera. Suture line dehiscence is a recognized complication of drains.14 Drains should not be placed directly under an incision line and should not exit through the suture line. Direct contact with a healing incision can lead to a foreign body reaction and increased risk for incisional complications.14

Blockage

Closed suction drains can become clogged or lose suction, causing drain failure. Fenestrated drains placed in the abdominal cavity can become occluded by omentum. To decrease the risk for omental occlusion, the drain can be placed between the liver and the diaphragm (FIGURE 9). Clogging is often identified when drains are pulled and clots and fibrinous material are noted to have taken the shape of the drain (FIGURE 10).

FIGURE 9. Postoperative ventrodorsal radiograph showing placement of a Jackson-Pratt drain in the abdominal cavity. The drain is placed in the space between the liver and diaphragm to limit occlusion by the omentum.

FIGURE 10. Blood clots and fibrinous debris removed from a Jackson-Pratt drain. Buildup of such debris over time can block drainage, causing a clinician to incorrectly believe that the drainage itself has decreased and to prematurely remove the drain. Periodic flushing of drains with sterile saline can delay drain occlusion.

Drain Failure

Loss of negative pressure can result in drain failure if the tube exit site is substantially larger than the tube and a purse-string suture is not placed. Loss of suction can also be caused by dehiscence of the wound closure or incision.

Electrolyte Imbalance

A major complication of drain use can be changes in electrolyte and/or serum protein levels. Electrolytes should be monitored closely in cases of high fluid production because loss of large volumes of proteinaceous fluid can lead to metabolic derangements and hypoproteinemia.16,17

Pneumothorax

Thoracostomy tube complications can be life-threatening. If the system suddenly becomes open, severe pneumothorax can ensue. This event can be avoided by providing redundant systems to ensure that accidental opening does not occur. A simple system is placement of a clamp and a 3-way stopco*ck on the tube. Adequate staff training should minimize accidental opening of both the stopco*ck and clamp; however, should this occur, negative pressure can be rapidly re-established if the tube is still in place.

In addition to knowing the indications for drain use, different drain types, benefits and drawbacks of each drain type, and common complications, successful drain use also involves proper drain placement, monitoring, and timing of removal. Knowledge of these concepts will help you maximize the effectiveness of drains while minimizing complications. These concepts will be covered in part 2 of this review.

References

  1. Campbell BG. Bandages and drains. In: Tobias K, Johnston S, eds. Veterinary Surgery: Small Animal. 1st ed. St. Louis, MO: Elsevier; 2012:221-230.
  2. Liptak JM. The principles of surgical oncology: surgery and multimodal therapy. Compend Contin Educ Vet 2009;31(9):E1-14.
  3. Bristow PC, Halfacree ZJ, Baines SJ. A retrospective study of the use of active suction wound drains in dogs and cats. J Sm Anim Pract 2015;56(5):325-330.
  4. Waldron DR, Zimmerman-Pope N. Superficial skin wounds. In: Slatter DH, ed. Textbook of Small Animal Surgery. 3rd ed. Philadelphia, PA: Elsevier; 2003:259-273.
  5. Pavletic MM. Wound drainage systems. In: Pavletic MM. Atlas of Small Animal Wound Management and Reconstructive Surgery. 3rd ed. Ames, IA: Wiley-Blackwell; 2010:52-60.
  6. Waldron DR, Trevor P. Management of superficial skin wounds, In: Slatter DH, ed. Textbook of Small Animal Surgery. Philadelphia, PA: WB Saunders;1993:269.
  7. Monnet E. Pleura and pleural space. In: Slatter DH, ed. Textbook of Small Animal Surgery. 3rd ed. Philadelphia, PA: Elsevier; 2003:387-405.
  8. Fetzer TJ, Walker JM, Bach JF. Comparison of the efficacy of small and large-bore thoracostomy tubes for pleural space evacuation in canine cadavers. J Vet Emerg Crit Care (San Antonio) 2017;27(3):301-306.
  9. Baldwin C, Potter M, Clayton E, et al. Topical negative pressure stimulates endothelial migration and proliferation: a suggested mechanism for improved integration of Integra. Ann Plast Surg 2009;62:92-96.
  10. Derrick KL, Lessing MC. Genomic and proteomic evaluation of tissue quality of porcine wounds treated with negative pressure wound therapy in continuous, noncontinuous, and instillation modes. Eplasty 2014;4:14.
  11. Stanley BJ. Negative pressure wound therapy. Vet Clin North Am Small Anim Pract 2017;47(6):1203-1220.
  12. Morykwas MJ, Argenta LC, Shelton-Brown EI, et al. Vacuum-assisted closure: a new method for wound control and treatment: animal studies and basic foundation. Ann Plast Surg 1997;38:553-562.
  13. Stanley BJ, Pitt KA, Weder CD, et al. Effects of negative pressure wound therapy on healing of free full-thickness skin grafts in dogs.
    Vet Surg 2013;42:511-522.
  14. Miller CW. Bandages and drains. In: Slatter DH, ed. Textbook of Small Animal Surgery. 3rd ed. Philadelphia, PA: Elsevier; 2003:244-249.
  15. Raves JJ, Slifkin M, Diamond DL. A bacteriologic study comparing closed suction and simple conduit drainage. Am J Surg 1984;148(5):618-620.
  16. Cioffi KM, Schmiedt CW, Cornell KK, Radlinsky MG. Retrospective evaluation of vacuum-assisted peritoneal drainage for the treatment of septic peritonitis in dogs and cats: 8 cases (2003–2010). J Vet Emerg Crit Care (San Antonio) 2012;22(5):601-609.
  17. Mueller MG, Ludwig LL, Barton LJ. Use of closed-suction drains to treat generalized peritonitis in dogs and cats: 40 cases (1997–1999). JAVMA 2001;219(6):789-794.
  18. Lynch AM, Bound NJ, Halfacree ZJ, Baines S. Postoperative haemorrhage associated with active suction drains in two dogs. J Small Anim Pract 2011;52(3):172-174.
Surgical Drains: Indications, Types, and Complications (2024)

FAQs

What are the types of surgical drains? ›

Drains are classified by various systems: open or closed and passive or active. Passive drains rely on gravity, body movement, pressure differentials, or overflow to move fluid or gas; active drains use intermittent or continuous negative pressure to pull fluid or gas from a wound or body cavity.

What are the 4 types of wound drainage? ›

Drainage can be (1) serous (clear and thin; may be present in a healthy, healing wound), (2) serosanguineous (containing blood; may also be present in a healthy, healing wound), (3) sanguineous (primarily blood), or (4) purulent (thick, white, and pus-like; may be indicative of infection and should be cultured).

How many types of drains are there? ›

There are two types of artificial drainage: surface drainage and subsurface drainage.

What are surgical drains used for? ›

Surgical drains are tubes placed near surgical incisions in the post-operative patient, to remove pus, blood or other fluid, preventing it from accumulating in the body.

What's a drain? ›

/ (dreɪn) / noun. a pipe or channel that carries off water, sewage, etc. an instance or cause of continuous diminution in resources or energy; depletion. surgery a device, such as a tube, for insertion into a wound, incision, or bodily cavity to drain off pus, etc.

What are the 4 types of exudate? ›

Types of Exudate
  • Serous – a clear, thin and watery plasma. ...
  • Sanguinous – a fresh bleeding, seen in deep partial- and full-thickness wounds. ...
  • Serosanguineous – thin, watery and pale red to pink in color.
  • Seropurulent – thin, watery, cloudy and yellow to tan in color.
29 Jan 2016

What are the types of wound? ›

Types of Wounds
  • Penetrating wounds. Puncture wounds. Surgical wounds and incisions. Thermal, chemical or electric burns. Bites and stings. Gunshot wounds, or other high velocity projectiles that can penetrate the body.
  • Blunt force trauma. Abrasions. Lacerations. Skin tears.

What type of drainage is blood? ›

Sanguineous drainage refers to the leakage of fresh blood from an open wound. This type of drainage is bright red in color and has a syrup-like consistency.

What are the five types of drainage? ›

  • Dendritic drainage pattern– ...
  • Parallel drainage pattern- ...
  • Trellis Drainage Pattern– ...
  • Rectangular Drainage Pattern– ...
  • Radial Drainage Pattern– ...
  • Centripetal Drainage Pattern– ...
  • Deranged Drainage Pattern- ...
  • Angular Drainage Pattern-

What are the methods of drainage? ›

The conventional engineering-based techniques most commonly used to drain excess water from land are: surface drainage, horizontal subsurface drainage and vertical subsurface drainage.

What is the importance of drainage? ›

Drainage ensures that the soil is properly aerated. If you have excess or standing water it can choke your crops. Drainage reduces soil and nutrient loss from runoff and can help avoid soil erosion. Drainage on hill slopes helps to reduce the risk of soil slippage.

What is normal drainage after surgery? ›

A mild amount of drainage from the incision is normal. If the drainage fluid is thin, watery, and pinkish red, there is likely nothing to be concerned about. However, there are instances in which you should be concerned about drainage from your incision.

Why are drains used for wound care? ›

Surgical wound drainage is recognized as a key element in facilitating the healing process. Wound drainage systems are designed to allow enough moisture to remain in tissues to promote regeneration and lessen inflammation, while removing excess exudate or material that may hamper the healing process.

What is a drain study? ›

In percutaneous abscess drainage, an interventional radiologist uses imaging guidance (CT, ultrasound or fluoroscopy) to place a thin needle into the abscess to obtain a sample of the infected fluid from an area of the body such as the chest, abdomen or pelvis.

What complications can occur with drain tubes? ›

Surgical drain and catheter-related complications can occur. These include fragmentation of the drain in the abdomen, pain, infection, loss of function due to obstruction, perforation of visceral organs and probable problems regarding drain withdrawal (3, 4, 7, 8).

How do you remove a surgical drain tube? ›

Grip the drain with the fingers of one hand, close to where it comes out of your body. With the fingers of your other hand, squeeze down the length of the tube. Start where it comes out of your body and move toward the drainage bulb. This is called "stripping" the drain.

How long should a wound drain? ›

Serous and serosanguinous drainage are normal for the first two or three days. But you should watch for signs that the amount of blood mixed with serum is increasing. If this happens, see your doctor. Paying close attention to a wound as it heals is vital.

What is drain person? ›

An emotionally draining person is typically on the high end of the Neuroticism personality dimension. They're constantly negative, worried, anxious, and nervous. All of us experience these feelings from time to time, but for neurotic personalities, these experiences tend to be sticky.

What is drainage blockage? ›

This means your drain is blocked and something is caught somewhere in the pipes, causing an obstruction. Here at Coastal Drains we are fully equipped to deal with problems like these but we are keen to equip you as well so that you don't have to worry about getting your wallet out to fix the problem.

Is the drainage system? ›

The flow of water through well-defined channels is known as drainage and the network of such channels is called a “drainage system”. The drainage system of an area is the outcome of the geological time period, nature and structure of rocks, slope, topography, amount of water flowing and the periodicity of flow.

What color is serous fluid? ›

Serous drainage is composed mainly of plasma. It is often thin and watery and will usually have a clear to yellowish or brownish appearance. Small amounts of serous drainage are normal during the first stages of healing.

What color is exudate? ›

Exudate is usually amber or straw coloured, similar to plasma (Davies, 2012). Any change in colour can indicate a possible problem. Green usually indicates bacterial infection practice.

What is wound drainage called? ›

Purulent drainage is a sign of infection. It's a white, yellow, or brown fluid and might be slightly thick in texture. It's made up of white blood cells trying to fight the infection, plus the residue from any bacteria pushed out of the wound. There may be an unpleasant smell to the fluid, as well.

What are the 5 types of open wounds? ›

Types
  • Abrasion. An abrasion wound occurs when the skin rubs or slides against a rough surface. ...
  • Laceration. A laceration is a deep opening or a tear in the skin. ...
  • Avulsion. An avulsion involves forcefully tearing away the skin and underlying tissue. ...
  • Puncture. A puncture wound is a small hole in the soft tissue. ...
  • Incision.
23 May 2019

What color is pus? ›

Pus is a thick fluid containing dead tissue, cells, and bacteria. Your body often produces it when it's fighting off an infection, especially infections caused by bacteria. Depending on the location and type of infection, pus can be many colors, including white, yellow, green, and brown.

When should surgical drains be removed? ›

Your surgeon will usually remove the bulb when drainage is below 25 ml per day for two days in a row. On average, JP drains can continue to drain for 1 to 5 weeks. Keep a log and bring it to the clinic for discussion so your surgical team can determine the best time to remove the drain.

What is yellow fluid from wound? ›

Wound drainage that has a milky texture and is gray, yellow, or green is known as purulent drainage. It could be a sign of infection. The drainage is thicker because it contains microorganisms, decaying bacteria, and white blood cells that attacked the site of the infection. It may have a strong smell too.

What are the 3 types of drainage patterns? ›

Drainage patterns
  • Dendritic drainage pattern. Dendritic drainage systems (from Greek δενδρίτης, dendrites, "of or like a tree") are not straight and are the most common form of the drainage system. ...
  • Trellis drainage pattern. ...
  • Rectangular drainage pattern. ...
  • Radial drainage pattern. ...
  • Deranged drainage pattern.

What are effects of drainage? ›

Poor drainage caused by the shape of the landscape or inadequate drainage systems can damage buildings and move soil from where it's needed to where it causes trouble. The effects of poor drainage systems extend beyond single properties and can have an impact on roads, waterways, and health.

What is the main drainage system? ›

The main drainage system is a water-conveyance system that receives water from the field drainage systems, surface runoff and groundwater flow, and transports it to the outlet point. The main drainage system consists of some collector drains and a main drainage canal.

What are the causes of drainage? ›

Six common causes of drainage failure – and how to address them
  • Cause 1: tree roots. ...
  • Cause 2: land movement and subsidence. ...
  • Cause 3: the impact of industrial and heavy goods traffic. ...
  • Cause 4: attack from chemical waste such as sugar or acid. ...
  • Cause 5: pipe infiltration leading to encrustations. ...
  • Cause 6: site activity.

What is a good drainage system? ›

The house drainage system needs to have enough headroom to handle sudden downpours without compromising its performance. Gutters need to be properly sized according to the roof slope, the local average rainfall, and other factors. It also has to have downspouts to match.

What are the factors affecting drainage system? ›

Following factors affect the drainage system of a river:
  • Topography of the land.
  • The gradient of the land.
  • Geological time period.
  • Nature and structure of rocks.
  • Amount of water flowing.
  • Periodicity of the flow.

What is normal JP drain output? ›

The drain(s) is left in place until drainage is approximately 30 cc's or less (or 30 ml's, or 1 ounce) per drain for each of 2 consecutive days. The fluid which collects in the bulb is normally very red at first, changing to more orange or straw-colored the longer it is in place.

What is an abdominal drain? ›

Abdominal drainage is a procedure to drain fluid from the peritoneal cavity, the space between the abdominal wall and organs. Inflammation, infection and traumatic injury, among other things, can cause fluid to build up in the cavity. The fluid is called ascites.

What happens after drains are removed? ›

Answer: Fluid after drain removal

Your body will naturally absorb the drainage as long as it is not excessive and decreasing in production. If the fluid continues to accumulate, then you can develop a seroma (fluid collection).

How is drain suction maintained? ›

The drain should be emptied as often as possible so that the bulb can be compressed fully to maintain suction. In general, this is usually done every four to six hours the first few days until the amount decreases. The drain should remain in place until your doctor tells you it is okay to be removed.

What is suction drain? ›

Suction drains are appliances used to collect blood, pus, or body fluids. They are active drains that maintain a negative pressure gradient. The collection reservoir of an active drain collects fluid by exchanging negative pressure, and the drain may become ineffective if the vacuum is lost.

What is a passive drain? ›

Passive Wound Drainage is a closed system designed for passive post-operative wound drainage. The passive wound drainage system is connected to a spiral drain which is placed directly into the surgical wound.

How do you drain an infection? ›

Abscess drainage is usually a safe and effective way of treating a bacterial infection of the skin. A doctor will numb the area around the abscess, make a small incision, and allow the pus inside to drain. This, and sometimes a course of antibiotics, is really all that's involved.

Which instrument is used to drain an abscess? ›

It is performed by treating the area with an antiseptic, such as iodine-based solution, and then making a small incision to puncture the skin using a sterile instrument such as a sharp needle or a pointed scalpel. This allows the pus fluid to escape by draining out through the incision.

What size abscess should be drained? ›

Conclusion. This retrospective data suggests that abscesses greater than 0.4 cm in depth from the skin surface may require a drainage procedure. Those less than 0.4 cm in depth may not require a drainage procedure and may be safely treated with antibiotics alone.

What are the two types of drainage systems? ›

Types of Drainage Systems

There are two main types of drainage system options: surface drains and french drains.

How long does a surgical drain stay in? ›

Your surgeon will usually remove the bulb when drainage is below 25 ml per day for two days in a row. On average, JP drains can continue to drain for 1 to 5 weeks. Keep a log and bring it to the clinic for discussion so your surgical team can determine the best time to remove the drain.

What is a Penrose drain used for? ›

A Penrose drain is a soft, flat, flexible tube made of latex. It lets blood and other fluids move out of the area of your surgery. This keeps fluid from collecting under your incision (surgical cut) and causing infection.

Is a Penrose a simple drain? ›

Simple flat drain that can be used to wick fluid from abdominal surgical sites.

What are methods of drainage? ›

Drainage Types

The two general types of drainage practices are surface and subsurface. Surface drainage is the removal of excess water from the soil surface. Subsurface drainage is the removal of water from the soil profile.

Can I shower with surgical drains? ›

Conclusions Postoperative showering for patients with closed suction drainage is safe and does not increase the incidence of postoperative complications, including surgical site infection.

Can surgical drains get clogged? ›

A surgical drain can become clogged at the openings or along the length of the tube, and thus, prevent drainage of fluids.

What happens after drains are removed? ›

Answer: Fluid after drain removal

Your body will naturally absorb the drainage as long as it is not excessive and decreasing in production. If the fluid continues to accumulate, then you can develop a seroma (fluid collection).

What is a Hemovac drain used for? ›

A Hemovac drain is placed under your skin during surgery. This drain removes any blood or other fluids that might build up in this area. You can go home with the drain still in place.

When is a Jackson Pratt drain used? ›

A Jackson Pratt drain is used to help empty excess fluid from the body after surgery. Use of a drain can help in the healing process.

What is the difference between serous and Serosanguinous drainage? ›

Serosanguineous fluid is the most common type of exudate secreted by wounds in comparison to serous, sanguineous, and purulent drainage. Serous drainage is a clear, thin, and watery exudate that typically appears during the inflammatory stage of wound healing.

What is a passive drain? ›

Passive Wound Drainage is a closed system designed for passive post-operative wound drainage. The passive wound drainage system is connected to a spiral drain which is placed directly into the surgical wound.

What is a pencil drain? ›

A Penrose drain is a soft, flexible rubber tube used as a surgical drain, to prevent the buildup of fluid in a surgical site.

What is an IP drain? ›

An intraperitoneal drain (IP drain) is a thin tube placed into the abdomen (belly). It is used to remove fluid from the intraperitoneal space. There are two kinds of IP drains: A tube comes out of the skin and can be attached to a drainage container when needed.

Top Articles
Latest Posts
Article information

Author: Nathanial Hackett

Last Updated:

Views: 6492

Rating: 4.1 / 5 (72 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Nathanial Hackett

Birthday: 1997-10-09

Address: Apt. 935 264 Abshire Canyon, South Nerissachester, NM 01800

Phone: +9752624861224

Job: Forward Technology Assistant

Hobby: Listening to music, Shopping, Vacation, Baton twirling, Flower arranging, Blacksmithing, Do it yourself

Introduction: My name is Nathanial Hackett, I am a lovely, curious, smiling, lively, thoughtful, courageous, lively person who loves writing and wants to share my knowledge and understanding with you.